GROUND FAULT CIRCUIT BREAKER, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 30 MILLIAMPERE TRIP SENSITIVITY; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL
Tag: electrical breakers
Cutler Hammer BW2175
CIRCUIT BREAKER, THERMAL MAGNETIC, MAIN; 2 POLE; 208 VAC STAR/120 VAC, 240 VAC; 175 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER); APPROVAL UL 489; USED ON LOAD CENTER
Cutler Hammer QBGFEP2050
GROUND FAULT CIRCUIT BREAKER, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 30 MILLIAMPERE TRIP SENSITIVITY; BOLT ON MOUNTING; APPROVAL UL 489; QUICKLAG[R] BRAND; QBGFEP MODEL
Cutler Hammer BW2200
CIRCUIT BREAKER, THERMAL MAGNETIC, MAIN; 2 POLE; 208 VAC STAR/120 VAC, 240 VAC; 200 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER); APPROVAL UL 489; USED ON LOAD CENTER
Cutler Hammer QCGF1015
GROUND FAULT CIRCUIT BREAKER, THERMAL MAGNETIC; 1 POLE; 120 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; RING LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE)
Cutler Hammer QCGF1020
GROUND FAULT CIRCUIT BREAKER, THERMAL MAGNETIC; 1 POLE; 120 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; RING LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE)
Cutler Hammer QCGF1030
GROUND FAULT CIRCUIT BREAKER, THERMAL MAGNETIC; 1 POLE; 120 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; BOX LUG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE)
Cutler Hammer QCGF2015
CIRCUIT BREAKER, THERMAL MAGNETIC; 2 POLE; 120/240 V; 15 AMPERE; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; CABLE TERMINAL; SIZE 4.5 INCH X 6 INCH X 15.5 INCH; APPROVAL UL 489, UL 943, CSA; OCGF MODEL
Cutler Hammer QCGF2020
GROUND FAULT CIRCUIT BREAKER, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; RING LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL
Cutler Hammer QCGF2030
GROUND FAULT CIRCUIT BREAKER, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; BOX LUG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL