Cutler Hammer QBGF1030

THERMAL MAGNETIC; 1 POLE; 120 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER, LOAD); BOLT ON MOUNTING

Cutler Hammer QBGFEP1030

GROUND FAULT CIRCUIT BREAKER, THERMAL MAGNETIC; 1 POLE; 120 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 30 MILLIAMPERE TRIP SENSITIVITY; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL

Cutler Hammer QBGF2015

THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER, LOAD); BOLT ON MOUNTING

Cutler Hammer QBGFEP2015

GROUND FAULT CIRCUIT BREAKER, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 30 MILLIAMPERE TRIP SENSITIVITY; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL

Cutler Hammer QC3040H

THERMAL MAGNETIC; 3 POLE; 240 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD); CABLE IN, CABLE OUT MOUNTING; APPROVAL UL 489, CSA

Cutler Hammer QC3050H

THERMAL MAGNETIC; 3 POLE; 240 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD); CABLE IN, CABLE OUT MOUNTING; APPROVAL UL 489, CSA

Cutler Hammer QC3060H

THERMAL MAGNETIC; 3 POLE; 240 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD); CABLE IN, CABLE OUT MOUNTING; APPROVAL UL 489, CSA

Cutler Hammer QC3070H

THERMAL MAGNETIC; 3 POLE; 240 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 8 TO 1/0 AWG ALUMINUM/COPPER (LOAD); CABLE IN, CABLE OUT MOUNTING; APPROVAL UL 489, CSA

Cutler Hammer QC3080H

THERMAL MAGNETIC; 3 POLE; 240 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 8 TO 1/0 AWG ALUMINUM/COPPER (LOAD); CABLE IN, CABLE OUT MOUNTING; APPROVAL UL 489, CSA

Cutler Hammer QC3090H

THERMAL MAGNETIC; 3 POLE; 240 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 8 TO 1/0 AWG ALUMINUM/COPPER (LOAD); CABLE IN, CABLE OUT MOUNTING; APPROVAL UL 489, CSA