CIRCUIT BREAKER, COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 225 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; LINE TERMINAL TERMINAL; WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER); APPROVAL UL 489; USED ON LOAD CENTER
Author: admin
Cutler Hammer CAH2100
MOLDED CASE, THERMAL MAGNETIC; CAH FRAME; 240 VAC; 100 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 22 KILOAMPERE; TERMINAL LINE TERMINAL, LOAD TERMINAL; APPROVAL UL; AB DE-ION[R] BRAND; CAH MODEL
Cutler Hammer QBGF1030
THERMAL MAGNETIC; 1 POLE; 120 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER, LOAD); BOLT ON MOUNTING
Cutler Hammer QBGF2015
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER, LOAD); BOLT ON MOUNTING
Cutler Hammer QBGF2020
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER, LOAD); BOLT ON MOUNTING
Cutler Hammer QBGF2030
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER, LOAD); BOLT ON MOUNTING
Cutler Hammer QBGF2040
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 8 AWG (COPPER, LOAD); BOLT ON MOUNTING
Cutler Hammer QBGF2050
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; BOLT ON MOUNTING; APPROVAL UL 489; QUICKLAG[R] BRAND; QBGF MODEL
Cutler Hammer QCGF1015
GROUND FAULT CIRCUIT BREAKER, THERMAL MAGNETIC; 1 POLE; 120 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; RING LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE)
Cutler Hammer QCGF1020
GROUND FAULT CIRCUIT BREAKER, THERMAL MAGNETIC; 1 POLE; 120 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; RING LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE)