Cutler Hammer MDL3700

MOLDED CASE, THERMAL MAGNETIC; MDL FRAME; 600 VAC AT 50/60 HZ; 700 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 50 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VDC (UL/CSA)

Cutler Hammer MDL3800

MOLDED CASE, THERMAL MAGNETIC; MDL FRAME; 600 VAC AT 50/60 HZ; 800 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 50 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VDC (UL/CSA)

Cutler Hammer MDL3800WK

MOLDED CASE CIRCUIT BREAKER, MAGNETIC, MOLDED CASE; M FRAME; 600 VAC AT 50/60 HZ, 250 VDC; 800 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 50 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VDC (UL)

Cutler Hammer MDL3800F

THERMAL MAGNETIC, ELECTRONIC RMS 310 TRIP, MDL FRAME; 600 VAC AT 50/60 HZ; 800 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 50 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VDC (UL, CSA)

Cutler Hammer HKD3250

MOLDED CASE, THERMAL MAGNETIC; HKD FRAME; 600 VAC AT 50/60 HZ; 250 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 35 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VDC (NEMA/UL/CSA)

Cutler Hammer EDH3200

MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 125 VDC; 200 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 10 KILOAMPERE AT 125 VDC (UL); 100 KILOAMPERE AT 220/240 VAC, 10 KILOAMPERE AT 125 VDC (IEC)

Cutler Hammer HKD3300

MOLDED CASE, THERMAL MAGNETIC; HKD FRAME; 600 VAC AT 50/60 HZ; 300 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 35 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VDC (NEMA/UL/CSA)

Cutler Hammer EDH3225

MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 125 VDC; 225 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 10 KILOAMPERE AT 125 VDC (UL); 100 KILOAMPERE AT 220/240 VAC, 10 KILOAMPERE AT 125 VDC (IEC)

Cutler Hammer HKD3350

MOLDED CASE, THERMAL MAGNETIC; HKD FRAME; 600 VAC AT 50/60 HZ; 350 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 35 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VDC (NEMA/UL/CSA)

Cutler Hammer JDC3100

MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; JDC FRAME; 600 VAC AT 50/60 HZ; 100 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 200 KILOAMPERE AT 240 VAC, 100 KILOAMPERE AT 480 VAC, 35 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VAC (UL)