High Interrupt rating –> “ELECTRONIC, MOLDED CASE; ND FRAME; 600 VAC AT 50/60 HZ; 1200 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 50 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL)
Tag: residential electrical service las vegas
Cutler Hammer LD3600WK
MOLDED CASE CIRCUIT BREAKER, MAGNETIC, MOLDED CASE SWITCH; LD FRAME; 600 VAC AT 50/60 HZ; 600 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 35 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VDC (UL)
Cutler Hammer LD3600F
THERMAL MAGNETIC, LD FRAME; 600 VAC AT 50/60 HZ; 600 AMPERE; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 35 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VDC (UL)
Cutler Hammer MDL3600
MOLDED CASE, THERMAL MAGNETIC; MDL FRAME; 600 VAC AT 50/60 HZ; 600 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 50 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VDC (UL/CSA)
Cutler Hammer HKD3150
MOLDED CASE, THERMAL MAGNETIC; HKD FRAME; 600 VAC AT 50/60 HZ; 150 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 35 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VDC (NEMA/UL/CSA)
Cutler Hammer HKD3175
MOLDED CASE, THERMAL MAGNETIC; HKD FRAME; 600 VAC AT 50/60 HZ; 175 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 35 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VDC (NEMA/UL/CSA)
Cutler Hammer HKD3200
MOLDED CASE, THERMAL MAGNETIC; HKD FRAME; 600 VAC AT 50/60 HZ; 200 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 35 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VDC (NEMA/UL/CSA)
Cutler Hammer HKD3225
MOLDED CASE, THERMAL MAGNETIC; HKD FRAME; 600 VAC AT 50/60 HZ; 225 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 35 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VDC (NEMA/UL/CSA)
Cutler Hammer HKD3250
MOLDED CASE, THERMAL MAGNETIC; HKD FRAME; 600 VAC AT 50/60 HZ; 250 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 35 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VDC (NEMA/UL/CSA)
Cutler Hammer EDH3200
MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 125 VDC; 200 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 10 KILOAMPERE AT 125 VDC (UL); 100 KILOAMPERE AT 220/240 VAC, 10 KILOAMPERE AT 125 VDC (IEC)