Cutler Hammer BR230ST

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 VAC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL; WITH 120 V SHUNT TRIP

Cutler Hammer CL220

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 V; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; CL MODEL

Cutler Hammer BR240ST

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 VAC; 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL; WITH 120 V SHUNT TRIP

Cutler Hammer BR250ST

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 VAC; 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL; WITH 120 V SHUNT TRIP

Cutler Hammer BR260ST

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 VAC; 60 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 4 TO 1/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL; WITH 120 V SHUNT TRIP

Cutler Hammer BR2100ST

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 VAC; 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 4 TO 1/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL; WITH 120 V SHUNT TRIP

Cutler Hammer BR2125ST

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 VAC; 125 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL; WITH 120 V SHUNT TRIP

Cutler Hammer BR320ST

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC, COMMON TRIP; 3 POLE; 240 VAC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL; WITH 120 V SHUNT TRIP

Cutler Hammer CHT2020

1 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON LOAD CENTER

Cutler Hammer BR415

THERMAL MAGNETIC, DUPLEX; 4 POLE; 120 VAC; 15 AMPERE (OUTSIDE POLE, CENTER POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL