Cutler Hammer QBGF1015

THERMAL MAGNETIC; 1 POLE; 120 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER, LOAD); BOLT ON MOUNTING

Cutler Hammer QBGF1020

THERMAL MAGNETIC; 1 POLE; 120 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER, LOAD); BOLT ON MOUNTING

Cutler Hammer QBHW3100H

THERMAL MAGNETIC; 3 POLE; 240 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 22000 AMPERE; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 8 TO 1/0 AWG (ALUMINUM/COPPER, LOAD); BOLT ON MOUNTING; APPROVAL UL 489, CSA

Cutler Hammer BAB2020S

INDUSTRIAL CIRCUIT BREAKER, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL

Cutler Hammer BAB2030S

INDUSTRIAL CIRCUIT BREAKER, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL

Cutler Hammer BAB2040S

INDUSTRIAL CIRCUIT BREAKER, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489, CSA

Cutler Hammer BAB2050S

INDUSTRIAL CIRCUIT BREAKER, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489, CSA

Cutler Hammer BAB2060S

INDUSTRIAL CIRCUIT BREAKER, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL

Cutler Hammer BAB2070S

MINIATURE CIRCUIT BREAKER, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL

Cutler Hammer BAB2100S

INDUSTRIAL CIRCUIT BREAKER, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL