Cutler Hammer BR340ST

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC, COMMON TRIP; 3 POLE; 240 VAC; 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL; WITH 120 V SHUNT TRIP

Cutler Hammer BR350ST

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC, COMMON TRIP; 3 POLE; 240 VAC; 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL; WITH 120 V SHUNT TRIP

Cutler Hammer BR360ST

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC, COMMON TRIP; 3 POLE; 240 VAC; 60 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 4 TO 1/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL; WITH 120 V SHUNT TRIP

Cutler Hammer BR3100ST

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC, COMMON TRIP; 3 POLE; 240 VAC; 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 4 TO 1/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL; WITH 120 V SHUNT TRIP

Cutler Hammer CL115

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC; 1 POLE; 120/240 V; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; CL MODEL

Cutler Hammer BRD230250

THERMAL MAGNETIC, INDEPENDENT TRIP, QUADPLEX; 2 POLE; 120/240 VAC; 30 AMPERE (OUTSIDE POLE), 50 AMPERE (CENTER POLE, INDEPENDENT TRIP POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489

Cutler Hammer CL120

CIRCUIT BREAKER, 1 POLE; 120/240 V; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 1 INCH W; USED ON LOAD CENTER; CL MODEL

Cutler Hammer BR120ST

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL; WITH 120 V SHUNT TRIP

Cutler Hammer CL130

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC; 1 POLE; 120/240 V; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; CL MODEL

Cutler Hammer BR220ST

PLUG ON CIRCUIT BREAKER, THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL; WITH 120 V SHUNT TRIP