THERMAL MAGNETIC; 2 POLE; 480 STAR/277 VAC AT 50/60 HZ, 125/250 VDC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 STAR/277 VAC/250 VDC (UL); LUG TERMINAL; WIRE SIZE 12 TO 6 AWG ALUMINUM, 14 TO 6 AWG COPPER
Tag: siemens breaker
Siemens BQD360
MOLDED CASE, THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 60 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
Siemens BQD370
MOLDED CASE, THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 70 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
Siemens BQD380
MOLDED CASE, THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 80 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
Siemens BQD390
MOLDED CASE, THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 90 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
Siemens BQD3100
MOLDED CASE, THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 100 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
Siemens CQD115
THERMAL MAGNETIC; 1 POLE; 277 VAC AT 50/60 HZ, 125 VDC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC, 14 KILOAMPERE AT 277 VAC/125 VDC (UL); LUG TERMINAL; WIRE SIZE 12 TO 6 AWG ALUMINUM, 14 TO 6 AWG COPPER
Siemens CQD120
THERMAL MAGNETIC; 1 POLE; 277 VAC AT 50/60 HZ, 125 VDC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC, 14 KILOAMPERE AT 277 VAC/125 VDC (UL); LUG TERMINAL; WIRE SIZE 12 TO 6 AWG ALUMINUM, 14 TO 6 AWG COPPER
Siemens BQD2100
MOLDED CASE, THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ, 125/250 VDC (UL); 100 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
Siemens BQD140
MOLDED CASE, THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ, 125 VDC (UL); 40 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC, 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H