Cutler Hammer CH215GF

COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 15 AMPERE; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; WIRE SIZE 14 TO 6 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489, CSA; USED ON LOADCENTER; CH MODEL

Cutler Hammer BR1520

THERMAL MAGNETIC, DUPLEX; 1 POLE; 120 VAC; 15 AMPERE (OUTSIDE POLE), 20 AMPERE (INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Cutler Hammer CH220GF

COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; WIRE SIZE 14 TO 6 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489, CSA; USED ON LOADCENTER; CH MODEL

Cutler Hammer BR2020

THERMAL MAGNETIC, DUPLEX; 2 POLE; 120 VAC; 20 AMPERE (OUTSIDE POLE, INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Cutler Hammer BR2030

CIRCUIT BREAKER, THERMAL MAGNETIC, DUPLEX; 1 POLE; 120 VAC; 20 AMPERE (OUTSIDE POLE), 30 AMPERE (CENTER POLE); INTERRUPTING RATING 10 KILOAMPERE; BOX LUG/CLAMP TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 1 INCH W

Cutler Hammer BR3030

THERMAL MAGNETIC, DUPLEX; 3 POLE; 120 VAC; 30 AMPERE (OUTSIDE POLE, INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Cutler Hammer BQ2202115

THERMAL MAGNETIC, INDEPENDENT TRIP, QUADPLEX; 2 POLE; 120/240 VAC; 15 AMPERE (OUTSIDE POLE), 20 AMPERE (CENTER POLE, INDEPENDENT TRIP POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489

Cutler Hammer BQ2302115

THERMAL MAGNETIC, INDEPENDENT TRIP, QUADPLEX; 2 POLE; 120/240 VAC; 15 AMPERE (OUTSIDE POLE), 30 AMPERE (CENTER POLE, INDEPENDENT TRIP POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489

Cutler Hammer BQ2402115

THERMAL MAGNETIC, INDEPENDENT TRIP, QUADPLEX; 2 POLE; 120/240 VAC; 15 AMPERE (OUTSIDE POLE), 40 AMPERE (CENTER POLE, INDEPENDENT TRIP POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489

Cutler Hammer BQ2502115

THERMAL MAGNETIC, INDEPENDENT TRIP, QUADPLEX; 2 POLE; 120/240 VAC; 15 AMPERE (OUTSIDE POLE), 50 AMPERE (CENTER POLE, INDEPENDENT TRIP POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489