Cutler Hammer EHD3080

MOLDED CASE, THERMAL MAGNETIC; F FRAME; 480 VAC AT 50/60 HZ, 250 VDC; 80 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 18 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 VAC, 10 KILOAMPERE AT 250 VDC (UL); TERMINAL STANDARD PRESSURE LOAD TERMINAL

Cutler Hammer EHD2040

MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240/480 VAC AT 50/60 HZ, 250 VDC (UL); 40 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 18 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 VAC, 10 KILOAMPERE AT 250 VDC (UL); TERMINAL STANDARD PRESSURE LOAD TERMINAL

Cutler Hammer EHD3090

MOLDED CASE, THERMAL MAGNETIC; F FRAME; 480 VAC AT 50/60 HZ, 250 VDC; 90 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 18 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 VAC, 10 KILOAMPERE AT 250 VDC (UL); TERMINAL STANDARD PRESSURE LOAD TERMINAL

Cutler Hammer EHD2050

MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240/480 VAC AT 50/60 HZ, 250 VDC (UL); 50 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 18 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 VAC, 10 KILOAMPERE AT 250 VDC (UL); TERMINAL STANDARD PRESSURE LOAD TERMINAL

Cutler Hammer GD3050

MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; G FRAME; 480 VAC AT 50/60 HZ, 250 VDC; 50 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 22 KILOAMPERE AT 480 VAC, 10 KILOAMPERE AT 250 VDC (UL)

Cutler Hammer GD3060

MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; G FRAME; 480 VAC AT 50/60 HZ, 250 VDC; 60 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 22 KILOAMPERE AT 480 VAC, 10 KILOAMPERE AT 250 VDC (UL)

Cutler Hammer GD3070

MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; G FRAME; 480 VAC AT 50/60 HZ, 250 VDC; 70 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 22 KILOAMPERE AT 480 VAC, 10 KILOAMPERE AT 250 VDC (UL)

Cutler Hammer GD3080

MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; G FRAME; 480 VAC AT 50/60 HZ, 250 VDC; 80 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 22 KILOAMPERE AT 480 VAC, 10 KILOAMPERE AT 250 VDC (UL)

Cutler Hammer GD3090

MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; G FRAME; 480 VAC AT 50/60 HZ, 250 VDC; 90 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 22 KILOAMPERE AT 480 VAC, 10 KILOAMPERE AT 250 VDC (UL)

Cutler Hammer GD3100

MOLDED CASE CIRCUIT BREAKER, THERMAL MAGNETIC; G FRAME; 480 VAC AT 50/60 HZ, 250 VDC; 100 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 22 KILOAMPERE AT 480 VAC, 10 KILOAMPERE AT 250 VDC (UL)