THERMAL MAGNETIC, DUPLEX; 4 POLE; 120 VAC; 30 AMPERE (OUTSIDE POLE, CENTER POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
Author: admin
Cutler Hammer BRD230240
THERMAL MAGNETIC, INDEPENDENT TRIP, QUADPLEX; 2 POLE; 120/240 VAC; 30 AMPERE (OUTSIDE POLE), 40 AMPERE (CENTER POLE, INDEPENDENT TRIP POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489
Cutler Hammer GFCB240
GROUND FAULT CIRCUIT BREAKER, COMMON TRIP; 2 POLE; 120/240 VAC; 40 AMPERE; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; WIRE SIZE 14 TO 4 AWG (COPPER); PLUG ON MOUNTING; USED ON LOADCENTER; GFCB MODEL
Cutler Hammer GFCB250
GROUND FAULT CIRCUIT BREAKER, COMMON TRIP; 2 POLE; 120/240 VAC; 50 AMPERE; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; WIRE SIZE 14 TO 4 AWG (COPPER); PLUG ON MOUNTING; USED ON LOADCENTER; GFCB MODEL
Cutler Hammer BR1515
THERMAL MAGNETIC, DUPLEX; 1 POLE; 120 VAC; 15 AMPERE (OUTSIDE POLE, INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
Cutler Hammer BR1520
THERMAL MAGNETIC, DUPLEX; 1 POLE; 120 VAC; 15 AMPERE (OUTSIDE POLE), 20 AMPERE (INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
Cutler Hammer BR2020
THERMAL MAGNETIC, DUPLEX; 2 POLE; 120 VAC; 20 AMPERE (OUTSIDE POLE, INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
Cutler Hammer BR2030
CIRCUIT BREAKER, THERMAL MAGNETIC, DUPLEX; 1 POLE; 120 VAC; 20 AMPERE (OUTSIDE POLE), 30 AMPERE (CENTER POLE); INTERRUPTING RATING 10 KILOAMPERE; BOX LUG/CLAMP TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 1 INCH W
Cutler Hammer BR3030
THERMAL MAGNETIC, DUPLEX; 3 POLE; 120 VAC; 30 AMPERE (OUTSIDE POLE, INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
Cutler Hammer BQ2202115
THERMAL MAGNETIC, INDEPENDENT TRIP, QUADPLEX; 2 POLE; 120/240 VAC; 15 AMPERE (OUTSIDE POLE), 20 AMPERE (CENTER POLE, INDEPENDENT TRIP POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489