Square D QO270

COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 70 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING

Square D QO280

COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 80 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 2/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 3.5 INCH H; APPROVAL UL

Square D QO290

COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ; 90 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 3.5 INCH H

Square D QO2100

COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ; 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 3.5 INCH H

Square D QO2125

COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 125 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 2/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL

Square D QO315

COMMON TRIP, THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING

Square D QO320

COMMON TRIP, THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING

Square D QO325

COMMON TRIP, THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 25 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING

Square D QO220

COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING

Square D QO115

THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING