MOLDED CASE, THERMAL MAGNETIC; Q FRAME; 240 VAC AT 50/60 HZ (UL/CSA/NOM), 240/415 VAC AT 50/60 HZ (IEC); 125 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM), 10 KILOAMPERE AT 240/415 VAC (IEC)
Tag: electrical supply store las vegas
Square D QBL22150
MOLDED CASE, THERMAL MAGNETIC; Q FRAME; 240 VAC AT 50/60 HZ (UL/CSA/NOM), 240/415 VAC AT 50/60 HZ (IEC); 150 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM), 10 KILOAMPERE AT 240/415 VAC (IEC)
Square D QBL22175
MOLDED CASE, THERMAL MAGNETIC; Q FRAME; 240 VAC AT 50/60 HZ (UL/CSA/NOM), 240/415 VAC AT 50/60 HZ (IEC); 175 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM), 10 KILOAMPERE AT 240/415 VAC (IEC)
Square D QBL22200
MOLDED CASE, THERMAL MAGNETIC; Q FRAME; 240 VAC AT 50/60 HZ (UL/CSA/NOM), 240/415 VAC AT 50/60 HZ (IEC); 200 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM), 10 KILOAMPERE AT 240/415 VAC (IEC)
Square D HOM250
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 50 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 2.98 INCH D X 3.13 INCH H; APPROVAL UL; USED ON LOAD CENTER
Square D HOM260
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 60 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 2.98 INCH D X 3.13 INCH H; APPROVAL UL; USED ON LOAD CENTER
Square D HOM270
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 70 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 2.98 INCH D X 3.13 INCH H; APPROVAL UL; USED ON LOAD CENTER
Square D HOM290
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 90 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 2.98 INCH D X 3.13 INCH H; APPROVAL UL; USED ON LOAD CENTER
Square D HOM2100
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 100 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 2.98 INCH D X 3.13 INCH H; APPROVAL UL; USED ON LOAD CENTER
Square D HOM2125
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 125 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 2.98 INCH D X 3.13 INCH H; APPROVAL UL; USED ON LOAD CENTER