THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); LUG TERMINAL; WIRE SIZE 14 TO 2 AWG (ALUMINUM/COPPER); 35 MM DIN RAIL MOUNTING
Tag: cutler hammer breakers catalog
Square D QOU240
THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ; 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); LUG TERMINAL; WIRE SIZE 14 TO 2 AWG (ALUMINUM/COPPER); 35 MM DIN RAIL MOUNTING
Square D QOU250
THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ; 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); LUG TERMINAL; WIRE SIZE 14 TO 2 AWG (ALUMINUM/COPPER); 35 MM DIN RAIL MOUNTING
Square D QOU260
THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ; 60 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); LUG TERMINAL; WIRE SIZE 14 TO 2 AWG (ALUMINUM/COPPER); 35 MM DIN RAIL MOUNTING
Square D QOU270
THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ; 70 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); LUG TERMINAL; WIRE SIZE 14 TO 2 AWG (ALUMINUM/COPPER); 35 MM DIN RAIL MOUNTING
Square D QO215GF
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING
Square D QOU2100
THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ; 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 60 VDC (UL/CSA); LUG TERMINAL; WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); 35 MM DIN RAIL MOUNTING
Square D QO320
COMMON TRIP, THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING
Square D QO325
COMMON TRIP, THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 25 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING
Square D QO330
COMMON TRIP, THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING