Cutler Hammer KD3400KW

MOLDED CASE CIRCUIT BREAKER, MAGNETIC, MOLDED CASE SWITCH; KD FRAME; 600 VAC AT 50/60 HZ; 400 AMPERE AT 40 DEG C; 3 POLE

Cutler Hammer KD3400F

ELECTRONIC, KD FRAME; 600 VAC AT 50/60 HZ; 125 TO 400 AMPERE; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 35 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC, 10 KILOAMPERE AT 250 VDC (UL/CSA)

Cutler Hammer EDH3100

MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 125 VDC; 100 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 10 KILOAMPERE AT 125 VDC (UL); 100 KILOAMPERE AT 220/240 VAC, 10 KILOAMPERE AT 125 VDC (IEC)

Cutler Hammer EDH3125

MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 125 VDC; 125 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 10 KILOAMPERE AT 125 VDC (UL); 100 KILOAMPERE AT 220/240 VAC, 10 KILOAMPERE AT 125 VDC (IEC)

Cutler Hammer EDH3150

MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 125 VDC; 150 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 10 KILOAMPERE AT 125 VDC (UL); 100 KILOAMPERE AT 220/240 VAC, 10 KILOAMPERE AT 125 VDC (IEC)

Cutler Hammer EDH3175

MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 125 VDC; 175 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 10 KILOAMPERE AT 125 VDC (UL); 100 KILOAMPERE AT 220/240 VAC, 10 KILOAMPERE AT 125 VDC (IEC)

Cutler Hammer EDH3200

MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 125 VDC; 200 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 10 KILOAMPERE AT 125 VDC (UL); 100 KILOAMPERE AT 220/240 VAC, 10 KILOAMPERE AT 125 VDC (IEC)

Cutler Hammer EDH3225

MOLDED CASE, THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ, 125 VDC; 225 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 10 KILOAMPERE AT 125 VDC (UL); 100 KILOAMPERE AT 220/240 VAC, 10 KILOAMPERE AT 125 VDC (IEC)

Cutler Hammer JDC3100

MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; JDC FRAME; 600 VAC AT 50/60 HZ; 100 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 200 KILOAMPERE AT 240 VAC, 100 KILOAMPERE AT 480 VAC, 35 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VAC (UL)

Cutler Hammer JDC3125

MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; JDC FRAME; 600 VAC AT 50/60 HZ; 125 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 200 KILOAMPERE AT 240 VAC, 100 KILOAMPERE AT 480 VAC, 35 KILOAMPERE AT 600 VAC, 22 KILOAMPERE AT 250 VAC (UL)