Cutler Hammer QBHW2020

THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 22000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER, LOAD)

Cutler Hammer QBHW2015

THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 22000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER, LOAD)

Cutler Hammer QBHW1050

THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 42000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48 VAC, 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489, CSA

Cutler Hammer QBHW1040

THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 42000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48 VAC, 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489, CSA

Cutler Hammer QBHW1030

THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 42000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48 VAC, 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL

Cutler Hammer QBHW1020

THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 42000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48 VAC, 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL

Cutler Hammer QBHW1015

THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 42000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48 VAC, 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL

Cutler Hammer BAB1030S

INDUSTRIAL CIRCUIT BREAKER, THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48 VDC, 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL

Cutler Hammer BAB1020S

INDUSTRIAL CIRCUIT BREAKER, THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48 VDC, 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL

Cutler Hammer BAB1015S

INDUSTRIAL CIRCUIT BREAKER, THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48 VDC, 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL