Siemens CQD150

THERMAL MAGNETIC; 1 POLE; 277 VAC AT 50/60 HZ, 125 VDC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC, 14 KILOAMPERE AT 277 VAC/125 VDC (UL); LUG TERMINAL; WIRE SIZE 6 TO 1/0 AWG ALUMINUM, 8 TO 1 AWG COPPER

Siemens CQD160

THERMAL MAGNETIC; 1 POLE; 277 VAC AT 50/60 HZ, 125 VDC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC, 14 KILOAMPERE AT 277 VAC/125 VDC (UL); LUG TERMINAL; WIRE SIZE 6 TO 1/0 AWG ALUMINUM, 8 TO 1 AWG COPPER

Siemens BQD335

MOLDED CASE, THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 35 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H

Siemens CQD215

THERMAL MAGNETIC; 2 POLE; 480 STAR/277 VAC AT 50/60 HZ, 125/250 VDC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 STAR/277 VAC/250 VDC (UL); LUG TERMINAL; WIRE SIZE 12 TO 6 AWG ALUMINUM, 14 TO 6 AWG COPPER

Siemens BQD340

MOLDED CASE, THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 40 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H

Siemens CQD220

THERMAL MAGNETIC; 2 POLE; 480 STAR/277 VAC AT 50/60 HZ, 125/250 VDC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 STAR/277 VAC/250 VDC (UL); LUG TERMINAL; WIRE SIZE 12 TO 6 AWG ALUMINUM, 14 TO 6 AWG COPPER

Siemens BQD345

MOLDED CASE, THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 45 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H

Siemens CQD225

THERMAL MAGNETIC; 2 POLE; 480 STAR/277 VAC AT 50/60 HZ, 125/250 VDC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 STAR/277 VAC/250 VDC (UL); LUG TERMINAL; WIRE SIZE 12 TO 6 AWG ALUMINUM, 14 TO 6 AWG COPPER

Siemens BQD350

MOLDED CASE, THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 50 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H

Siemens CQD230

THERMAL MAGNETIC; 2 POLE; 480 STAR/277 VAC AT 50/60 HZ, 125/250 VDC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC, 14 KILOAMPERE AT 480 STAR/277 VAC/250 VDC (UL); LUG TERMINAL; WIRE SIZE 12 TO 6 AWG ALUMINUM, 14 TO 6 AWG COPPER