Square D QO130GF

GROUND FAULT PROTECTION – THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING

Square D QO315

COMMON TRIP, THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING

Square D QO320

COMMON TRIP, THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING

Square D QO325

COMMON TRIP, THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 25 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING

Square D QO330

COMMON TRIP, THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING

Square D QO335

COMMON TRIP, THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 35 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING

Square D QO340

COMMON TRIP, THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING

Square D QO345

COMMON TRIP, THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 45 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING

Square D QO350

COMMON TRIP, THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ, 48 VDC; 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC, 5 KILOAMPERE AT 48 VDC (UL/CSA); WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING

Square D QO360

COMMON TRIP, THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 60 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 2.25 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL; USED ON LOAD CENTER